Frame and installation system

Drywall Metal Door Frames

Commercial metal frames engineered for gypsum board and light-gauge stud wall openings, available in knock-down and welded configurations.

Slip-on KD or weldedSteel and wood door compatibleUL fire-rated options
Drywall metal door frame profile options

Technical product guide

Drywall Frame Construction, Anchors and Installation Options

Compare frame profiles, corner construction, wall anchors and dimensional requirements before preparing the opening schedule.

Compatible Door Leaves

Drywall frames can be prepared for commercial steel or wood door leaves when the leaf thickness, hinge locations, strike preparation and finished wall thickness are confirmed.

ST

Pair with Steel Door Leaves

Commonly used for mechanical rooms, utility closets and service corridors when a steel door leaf is specified.

WD

Pair with Wood Door Leaves

Wood door leaves can be paired with a suitable drywall frame for hotel rooms, offices and interior clinical areas, subject to the required rating and listed assembly.


Frame Construction & Options

Select the frame construction according to whether it will be installed before or after the drywall boards are finished.

Slip-On Knocked-Down (KD) Drywall Frames

Designed to fit over finished drywall returns. Interlocking mitered corners and adjustable anchors help the installer align and secure the frame; knock-down packing also reduces shipment volume.

Pre-Welded Drywall Frames

Face-welded corner joints are ground before finishing. These frames are normally installed during the stud-framing stage, before the drywall boards are fixed.


Technical Specifications Matrix

Technical ParametersNorth American Standard OptionsEngineering Details
Fire Codes ComplianceUL 10C / UL 10B / CAN/ULC-S104Certified for interior light-gauge stud drywall systems up to 90-minute fire ratings.
Material QualityASTM A653 / A653M Certified SteelStandard A60 Galvannealed. Ensures premium adhesion for interior topcoat painting without flaking.
Jamb Depth5-5/8", 5-7/8", 6-3/4", 8-1/4"Sized for standard steel studs with the specified layers of Type X drywall.
Throat Opening4-5/8" (for 3-5/8" Stud + 2x 1/2" Drywall)
4-7/8" (for 3-5/8" Stud + 2x 5/8" Drywall)
Net clearance includes standard 1/2" double-return bend on the frame edge to tightly hug the drywall board. Tolerances within ±1/16" (1.6mm) per NAAMM/HMMA 801.
Frame FaceStandard 2" (50.8mm) Profile FaceClean, minimalist aesthetic to complement upscale modern office interiors. Meets SDI 111.
Rabbet SizeActive Rabbet: 1-15/16" (49.2mm)
Inactive Rabbet: 1-9/16" (39.7mm)
Precision engineered to match standard 1-3/4" (44.4mm) steel or wood commercial doors.
Stop HeightStandard 5/8" (15.9mm) HeightThe center rib serves as a robust sound-deadening and intumescent smoke gasket position.
Hinge Reinforcements7 Gauge (4.5mm) Thick Steel PlatesPre-punched and tapped for 12-24 machine screws. Multi-spot welded to resist door sagging.
ClearancesStiles/Header: 1/8" (3.2mm)
Bottom/Sill: 3/4" (19.1mm) max
Strictly adheres to NFPA 80 standard requirements for fire door assembly clearance limits.
Silencers PrepPre-punched 9/32" (7.1mm) holes
3 per strike jamb / 2 per header
Factory-punched to receive standard pneumatic rubber silencers for impact dampening.

Specialized Drywall Anchoring Systems

To achieve a tight clamp and prevent frame shifting on drywall partitions, we utilize three distinct engineering anchor setups.

Compression Anchor (Plumb Adjust)

Located near the top of both jambs. Uses an adjustable screw mechanism inside the frame to exert pressure outward against the steel stud, locking the frame in perfect plumb alignment.

Base Strap Anchor (Snap-In)

Welded securely at the bottom of the jambs. Designed to be screwed or nailed directly into the floor runner tracks (bottom tracks) before the drywall partition is fully paneled.

Wood/Steel Stud Anchor

Flush-fit countersunk screw holes punched into the returns or rabbets. Perfect for fastening directly into structural wood studs or heavy metal stud vertical studs with drywall screws.


Buyer Frequently Asked Questions

Q: Can your Slip-On KD Drywall Frames be installed after the walls are completely painted?

A: Yes. Slip-on knock-down frames can be installed after the drywall finish when the finished wall thickness and opening dimensions have been confirmed.

Q: How do I confirm the throat opening for our stud wall?

A: We follow NAAMM/HMMA 801 and SDI 111 precise dimensions. For instance, if your wall budget specifies 3-5/8" steel studs with one layer of 5/8" Type X drywall on each side, the total wall thickness is 4-7/8". We will customize the throat size exactly to 4-7/8" with a strict ±1/16" tolerance to guarantee a snug clamp.

Q: Do these drywall frames achieve the same 90-minute UL fire certification when paired with wood doors?

A: The required rating must be checked against the listed door-and-frame assembly. Send the wall construction, frame profile, door type, glazing and hardware schedule so the available configuration can be confirmed before quotation.

Coordinate drywall frame dimensions before production

Send opening sizes, wall construction, rating requirements and the hardware schedule for technical review.

Request a Quote

Project RFQ Support

Submit your door schedule and project drawings

Send the opening schedule, wall conditions, rating requirements and hardware notes. Bastion Door can review the scope and prepare a practical factory-direct quotation route.

  • Door and hardware schedule review for commercial projects.
  • Frame type, fire rating, lockset and closer preparation checks.
  • Export packing, quantity grouping and project delivery support.

After submitting, you can attach PDF, DWG or Excel schedules on the contact page or send them by email for engineering review.