Lead-lined X-ray doors form part of a room shielding strategy. The door leaf, frame, viewing window, wall interface and hardware must be coordinated with the shielding design prepared for the project. Buyers should not select lead thickness or construction from a generic product image alone.
Begin with the shielding design
Provide the shielding schedule, consultant details or project specification that states the required lead equivalence and protected boundaries. Requirements may vary by room, equipment and opening, so each door mark should be checked against the current shielding information rather than copied from another project.
Coordinate the leaf, frame and wall interface
Confirm door size, handing, wall type, wall thickness and frame profile. The frame and surrounding interfaces should support shielding continuity as detailed by the project designer. Include jamb, head and floor conditions on the drawings, especially where different wall systems meet the opening.
Viewing windows and glazing
If a vision panel or adjacent observation window is required, state the visible size, position and specified lead equivalence. Glazing retention, frame details and interfaces should be reviewed with the complete opening. Do not assume ordinary fire-rated or safety glass provides the required radiation shielding.
Hardware and operating force
- Hinges or pivots selected for the finished door weight
- Lockset, closer and pull hardware requirements
- Access-control, interlock or door-contact preparation
- Emergency egress and room operating procedures
- Protection plates or edge details for clinical traffic
- Any separate fire-rating requirement for the opening
Information required for quotation
Send the door schedule, shielding details, opening dimensions, quantities, wall construction and hardware notes. Identify finishes, viewing windows, labels, documentation and installation scope. State the project destination and whether frames, glazing and hardware are included in the requested package.
Checks before production approval
Review shop drawings for dimensions, handing, lead equivalence, frame interfaces, viewing windows and hardware preparation. Confirm how the lead lining terminates at edges and interfaces according to the project shielding design. Installation responsibilities and site inspection requirements should also be agreed before delivery.
Avoid common procurement assumptions
Do not compare quotations only by door size and lead thickness. Check what is included in the frame, glazing, hardware, drawings, documents and packing. Ask suppliers to state exclusions and any information that remains subject to shielding-consultant approval.